HFX Performance
- Men
- Women
- Mission
CAUTION: adventure awaits
Real people. Real experiences. Real gear.
With the Ryder Fashion Jacket
Have a compelling story about how HFX Performance Apparel helped you step outside your comfort zone?
New Arrivals
Blaire Insulated Parka Jacket
Sienna Self Packable Light Weight Jacket
Kenzie Reversible Quilted Jacket
Poly Print Ski Jacket
Nolan Heavyweight Puffer Jacket
ON LOCATION
Tag along with us to Iceland and take a look behind-the-scenes of our Fall ’17 campaign shoot.
#HFXPerformance
Join the experience and follow us on Instagram for a look at all things HFX – and don’t forget to share where your HFX takes you.
INSPIRED BY THE ROAD LESS TRAVELED
We create essential gear that provides ultimate protection so you can focus on what matters most – the path that lies ahead.
HFX Shear Wall Panels
Easy to specify. Easy to install. Easy for the trades to work with.
Request More Information on HFX
Hardy Frame® HFX-Series Panel on Concrete Foundations
- Installation on nuts and washers provides for leveling at uneven concrete – and an open end box wrench may be used to secure connection from below. Allowable loads are less than installation directly on concrete. Confirm with design building professional prior to installation.
- Raised floor head out installations bypass wood framing to eliminate the effects of shrinkage and crushing, while providing a direct shear transfer to the foundation
Hardy Frame® HFX-Series Panel on Wood Sill Plate
- Panels installed on wood sill plates have more ductility but, for some sizes the allowable shear is less to account for crushing of wood below
- Allowable values have been reduced when necessary to maintain code drift limit (see HFX-Series Product Catalog Table 1.2)
Installation:
- Set bolts 4-1/4″ inches above concrete
- Moisture barrier (15# felt, Moist Stop, Etc.) recommended when installing on treated wood
Hardy Frame® HFX-Series Panel on Raised Floor
- Allowable values have been reduced when necessary to maintain code drift limit (see HFX-Series Product Catalog Table 1.3)
- Table values for Panels installed on a wood floor system assume installation with a Hardy Frame® Bearing Plate
Installation at raised floor head-out:
- Provides allowable values from HFX-Series Product Catalog Table 1.2A
- Provides a direct shear transfer to the foundation
- Requires less material by eliminating rim, Bearing Plate and bottom screw
Hardy Frame® HFX-Series Panel on Upper Floor
- Allowable values in Table 1.3A have been adjusted to maintain code drift limit while including the effects of crushing in wood members below.
- For “straight stack” installations, cumulative forces must be considered by the building design professional.
- For discontinuous systems, amplification factors must be considered by the Building Design Professional.
- Table values for Panels installed on a wood floor system assume installation of a Hardy Frame® Bearing Plate.
- For installations on beams, size plate washers on underside of wood beam to prevent crushing and include deflection from the overturning couple in the drift procedure.
Hardy Frame® “STK Washers” are required in the top of Panels when connecting to a hold down rod from above.Hardy Frame® “STK Panels” include pre-welded in the top channel.
Please use portrait orientation for a better experience.
HFX LTD Head Office
Solutions House,
Dunhams Lane,
Letchworth Garden City
Herts,
SG6 1BE
Suite 9, GEDDES HOUSE,
Livingston
Edinburgh EH54 6GU
Autotime (A division of HFX)
No 1, The Alcora building,
2nd floor
Mucklow Hill
Halesowen
B62 8DG